| Degree Of Protection (IP Rating) | IP20 |
|---|---|
| Depth | 126 |
| Height | 154 |
| Width | 45 |
| Number Of Auxiliary Contacts As Normally Closed Contact | 1 |
| Number Of Auxiliary Contacts As Normally Open Contact | 1 |
| Rated Control Supply Voltage At DC | 24 |
| Rated Operation Power At AC-3, 400 V | 5.5 |
| Type Of Electrical Connection Of Main Circuit | Screw Connection |
| Voltage Type For Actuating | AC/DC |
| Rail Mounting Possible | Yes |
| Supporting Protocol For AS-Interface Safety At Work | No |
| Supporting Protocol For ASI | No |
| Supporting Protocol For CAN | No |
| Supporting Protocol For Data-Highway | No |
| Supporting Protocol For DeviceNet | No |
| Supporting Protocol For DeviceNet Safety | No |
| Supporting Protocol For EtherNet/IP | No |
| Supporting Protocol For Foundation Fieldbus | No |
| Supporting Protocol For INTERBUS | No |
| Supporting Protocol For INTERBUS-Safety | No |
| Supporting Protocol For LON | No |
| Supporting Protocol For MODBUS | No |
| Supporting Protocol For Other Bus Systems | No |
| Supporting Protocol For PROFIBUS | No |
| Supporting Protocol For PROFINET CBA | No |
| Supporting Protocol For PROFINET IO | No |
| Supporting Protocol For PROFIsafe | No |
| Supporting Protocol For SafetyBUS P | No |
| Supporting Protocol For SERCOS | No |
| Supporting Protocol For SUCONET | No |
| Supporting Protocol For TCP/IP | No |
| Number Of Command Positions | 3 |
| Rated Control Supply Voltage At AC 50 Hz | 24 |
| Rated Control Supply Voltage At AC 60 Hz | 24 |
| Ambient Temperature, Upper Operating Limit | 70 |
| Coordination Class According To IEC 60947-4-3 | Class 2 |
| External Reset Possible | No |
| Kind Of Motor Starter | Direct Starter |
| Number Of Indicator Lights | 0 |
| Rated Conditional Short-circuit Current, Type 1, 480 Y/277 V | 10000 |
| Rated Conditional Short-circuit Current, Type 1, 600 Y/347 V | 4000 |
| Rated Conditional Short-circuit Current, Type 2, 230 V | 50000 |
| Rated Conditional Short-circuit Current, Type 2, 400 V | 50000 |
| Rated Operation Current Ie | 12 |
| Rated Operation Current At AC-3, 400 V | 12 |
| Rated Operation Power At AC-3, 230 V, 3-phase | 3 |
| Rated Power, 460 V, 60 Hz, 3-phase | 5.5 |
| Rated Power, 575 V, 60 Hz, 3-phase | 5.5 |
| Suitable For Emergency Stop | No |
| Type Of Electrical Connection For Auxiliary- And Control Current Circuit | Screw Connection |
| With Fuse | No |
| With Short-circuit Release | Yes |
| With Transformer | No |
| UK Mainland | Order by 2pm for Next Day Delivery* |
|---|---|
| Under £25.00 | £4.50 |
| Over £25.00 | FREE |
| UK Highlands & Islands | Order by 2pm for Next Day Delivery* |
|---|---|
| Under £80.00 | £15.00 |
| Over £80.00 | FREE |